{{title}}
Request a quote {{contactOpenText}}
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

Q46S/81 Dissolved Sulfide Monitor

The Q46S/81 Dissolved Sulfide Water Quality Monitor takes a different approach to dissolved sulfide concentration measurement, employing a unique gas-phase method to continuously monitor sulfide without contact between the sensor and the water sample.

Showing units in {{labelText}}
  • Parameters
    Dissolved Sulfide, Temperature
    Dissolved Sulfide, Temperature
Request a quote

High-Sensitivity Sulfide Monitoring

Sulfides can be found naturally in well water and can build up in wastewater collection systems due to anaerobic conditions frequently found there. In addition, sulfides are used in mercury removal processes and are frequently found in tanning wastes. In drinking water systems, sulfides cause taste and odor problems. In wastewater systems, sulfides cause damage to concrete structures in collection systems and contribute to odor problems in treatment facilities.

Measurement of dissolved sulfide concentrations has been done primarily by the use of analyzers employing ion-selective electrodes (ISE) for sensing. While providing adequate sensitivity, ISE-based systems require frequent zero and span adjustments to maintain measurement accuracy. Because of this, most ISE-based monitoring systems are relatively expensive and require frequent service.

Due to measuring sulfides in the solution being relatively difficult, the Q46S/81 Monitor takes a different approach to the measurement, employing a unique gas-phase method to continuously monitor sulfide without contact between the sensor and the water sample. In operation, a small amount of sample is pumped into the system and mixed with acid. In an acidic solution, the sulfide ion is converted to hydrogen sulfide gas The mixed sample flows into a special chamber where the hydrogen sulfide is stripped from the sample. A gas conditioning module prepares the gas sample for measurement before contact with a special H2S gas sensor designed for the system. Sensor signals are amplified and displayed on a large-format, backlit LCD display in the Q46S electronics unit.

Features

  • Improved method for measuring sulfides in solution
  • No contact between sensor and water sample

Market Applications

  • Drinking Water Treatment

    Drinking water treatment facilities have the critical job of producing a safe supply of high-quality drinking water. Complex operational processes demand the highest flow meter accuracy and reliability, as well as long-term stability and a low cost of ownership. Badger Meter water treatment solutions meet the challenge, assisting utility customers with increasing compliance levels, protecting treatment assets and providing opportunities for process optimization using predictive analytics.

    View Solutions
  • Wastewater Treatment

    Wastewater treatment facilities feature complex operational processes involving a wide range of flow measurement, water quality monitoring and toxic gas detection solutions, designed to conserve water, increase regulatory compliance and safeguard water quality, people and the environment. From individual monitors to multiparameter measurement, our versatile solutions deliver continuous and proactive monitoring for early event detection, odor control, pollution prevention, chemical management and toxic gas detection.

    View Solutions
  • Industrial Pre-Treatment

    Industrial pre-treatment is a crucial stage in the water cycle, occurring before wastewater enters municipal treatment facilities. It involves the removal of contaminants, pollutants, and other harmful substances from industrial wastewater streams to meet regulatory standards and protect the environment. This process typically includes physical, chemical, and biological treatment methods tailored to specific industrial processes and pollutants. By effectively pre-treating industrial wastewater, we can safeguard water quality, prevent damage to treatment infrastructure, and ensure the overall health of ecosystems downstream.

    View Solutions
  • Industrial Process

    The measurement and monitoring of flow, water quality and toxic and combustible gas plays a vital role in industrial processes for consistent delivery of quality control, personnel safety, environmental protection, process monitoring and optimization. Our comprehensive range of robust, real-time and reliable instrumentation provides dependable solutions that are easy to install, simple to maintain, creates safe areas of work and deliver increased regulation compliance.

    View Solutions

Product Documentation

Filter Documents
Filtered by:
Remove all filters
Document Type
{{isTruncated ? openText : closeText}}

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

We’re sorry, your request didn’t return any documents.

{{data.didYouMean[0]}}? Please check your search term.

Please try again or contact us

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page

Software & Firmware

Filter Downloads
Filtered by:
Remove all filters
Product Line
{{isTruncated ? openText : closeText}}
Product / Model

Before filtering by product or model, please select a brand from the filter above.

{{isTruncated ? openText : closeText}}
Download Type
Language
{{isTruncated ? openText : closeText}}

Displaying {{pageRange}} of {{data.totalResults}}

Updated September 16, 2024 | 4 KB Q46 Ethernet/IP Config File ATi See Release Notes
Updated September 16, 2024 | 4 KB Q46 Ethernet/IP Config File ATi See Release Notes
Updated October 10, 2024 | 2 KB Q46 Profibus DP Configuration File ATi See Release Notes
Updated October 10, 2024 | 2 KB Q46 Profibus DP Configuration File ATi See Release Notes
Updated October 10, 2024 | 1.74 MB ATI Graphing Utility Download Setup 0.0.3 ATi See Release Notes
Updated October 10, 2024 | 6.93 MB Datalogger Graphing Utility ATi See Release Notes
Updated October 10, 2024 | 6.93 MB Datalogger Graphing Utility ATi See Release Notes

We’re sorry, your request didn’t return any software or firmware.

Please try again or contact us

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page
We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837