ME Endpoint

The ORION® ME is a two-way water endpoint for mobile applications, delivering meter reading data and status information to power the BEACON® Software as a Service (SaaS) mobile solution.

Showing units in {{labelText}}
  • Temperature Range
    -40…60 °C
    -40...140 °F
  • Humidity
    0%…100% condensing
    0%…100% condensing
  • Battery
    One (1) lithium thionyl chloride C cell (nonreplaceable)
    One (1) lithium thionyl chloride C cell (nonreplaceable)
  • Battery Life
    20 years (calculated)
    20 years (calculated)
Request a quote

Accessible Data. Enhanced Customer Service.

The ORION ME endpoint captures data profile information wirelessly for mobile applications.

  • Easy Access to Data. Allows users to capture data profile information wirelessly without having to directly access the endpoint
  • Enhanced Customer Service. Ability to provide through data profile analysis

Product Certifications
Hazardous location certification for Orion ME Gas Integral Transmitter.

Product Specifications

Showing units in {{labelText}}
  • Dimensions
    5.125 in. (H); 1.75 in. (W) at top; 2.125 in. (W) at bottom
    5.125 in. (H); 1.75 in. (W) at top; 2.125 in. (W) at bottom
  • Broadcast Frequency
    FCC regulated 902…928 MHz frequency hopping modulation
    FCC regulated 902…928 MHz frequency hopping modulation
  • Operating Temperature Range
    -40…60° C (-40…140° F) based on storage and meter reading. RF output may be reduced by extremely low temperatures. The water meter should not be subjected to temperatures below freezing.
    -40…60° C (-40…140° F) based on storage and meter reading. RF output may be reduced by extremely low temperatures. The water meter should not be subjected to temperatures below freezing.
  • Humidity
    0%…100% condensing
    0%…100% condensing
  • Battery
    One (1) lithium thionyl chloride C cell (nonreplaceable)
    One (1) lithium thionyl chloride C cell (nonreplaceable)
  • Battery Life
    20 years (calculated)
    20 years (calculated)

Market Applications

  • Customer Water Usage

    Utilities play a pivotal role in drinking water management by ensuring the safe and reliable delivery of clean water to communities. Operating and maintaining vast infrastructure networks, utilities are responsible for sourcing, treating, and distributing water while adhering to stringent quality standards. These applications demand the highest level of accuracy, flexibility and reliability. Our water meters and flow monitoring technologies, coupled with powerful analytics software, provide end-to-end solutions that generate revenue, conserve water and improve customer service.

    View Solutions

Software

Filter Downloads
Filtered by:
Remove all filters
Product Line
{{isTruncated ? openText : closeText}}
Product / Model

Before filtering by product or model, please select a brand from the filter above.

{{isTruncated ? openText : closeText}}
Download Type
Language
{{isTruncated ? openText : closeText}}

Displaying {{pageRange}} of {{data.totalResults}}

Software | Version v1210-20100408 | Updated January 22, 2024 | 2.32 MB IR Programming Cable Driver AquaCUE ; BEACON ; Dynasonics ; E-Series ; High Resolution Encoders ; ORION See Release Notes
Software | Version v1210-20100408 | Updated January 22, 2024 | 2.32 MB IR Programming Cable Driver AquaCUE ; BEACON ; Dynasonics ; E-Series ; High Resolution Encoders ; ORION See Release Notes

We’re sorry, your request didn’t return any software or firmware.

Please try again or contact us

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page

Product Documentation

Filter Documents
Filtered by:
Remove all filters
Document Type
{{isTruncated ? openText : closeText}}

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

We’re sorry, your request didn’t return any documents.

{{data.didYouMean[0]}}? Please check your search term.

Please try again or contact us

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page
We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837