F12iS Toxic Gas Transmitter

The F12iS Toxic Gas Transmitter, enclosed in a NEMA 4X polycarbonate housing, is designed to measure toxic gases and oxygen in hazardous locations requiring an Intrinsically Safe (IS) device. While operating at intrinsically safe power levels, the F12iS is also available with our exclusive Auto-Test feature that verifies sensor function daily, virtually eliminating the need for manual bump tests.

Showing units in {{labelText}}
  • Parameters
    Acid Gases, Ammonia, Chlorine, Chlorine Dioxide, Formaldehyde, Hydrogen Chloride, Hydrogen Cyanide, Hydrogen Fluoride, Hydrogen Peroxide, Hydrogen Sulfide, Oxygen, Ozone, Sulfur Dioxide, Other Gases
    Acid Gases, Ammonia, Chlorine, Chlorine Dioxide, Formaldehyde, Hydrogen Chloride, Hydrogen Cyanide, Hydrogen Fluoride, Hydrogen Peroxide, Hydrogen Sulfide, Oxygen, Ozone, Sulfur Dioxide, Other Gases
Request a quote

Intrinsically Safe Gas Detector

The F12iS Toxic Gas Detector is designed to measure toxic gases and oxygen in hazardous locations requiring an Intrinsically Safe (IS) device. While operating at intrinsically safe power levels, the F12iS is also available with our exclusive Auto-Test* feature that verifies sensor function daily, virtually eliminating the need for manual bump tests.

For many toxic gases, we offer a unique sensor response testing system unmatched by any competitive gas transmitter. Even outdoors in high wind conditions, the Auto-Test system provides reliable response checks to ensure system integrity. Sensor response is verified with an actual gas sample that is generated on demand. Generators store run time information accessible to operators, and are automatically tested for compatibility with the installed electrochemical sensors.

F12 gas detectors provide useful features that simplify installation, operation, and maintenance. The 4-button keypad is used to configure the menu-driven setup pages. The display also provides alarm indication and complete menus for setting up operating parameters.

The F12/D, a non-iS version, is also available for non-hazardous locations. 

Features

  • Perfect choice for explosion-hazard environments
  • 60 different interchangeable smart sensors
  • AutoTest sensor verification*
  • Heated sensor option

*Dependent upon gas being monitored

Market Applications

  • Environmental Monitoring

    ​Environmental monitoring solutions are designed to protect the world’s most precious resource. Instruments are deployable throughout the network to measure a variety of parameters, collect baseline data and deliver a deeper understanding of trends that enable early event detection and response.

    View Solutions
  • Wastewater Treatment

    Wastewater treatment facilities feature complex operational processes involving a wide range of flow measurement, water quality monitoring and toxic gas detection solutions, designed to conserve water, increase regulatory compliance and safeguard water quality, people and the environment. From individual monitors to multiparameter measurement, our versatile solutions deliver continuous and proactive monitoring for early event detection, odor control, pollution prevention, chemical management and toxic gas detection.

    View Solutions
  • Drinking Water Treatment

    Drinking water treatment facilities have the critical job of producing a safe supply of high-quality drinking water. Complex operational processes demand the highest flow meter accuracy and reliability, as well as long-term stability and a low cost of ownership. Badger Meter water treatment solutions meet the challenge, assisting utility customers with increasing compliance levels, protecting treatment assets and providing opportunities for process optimization using predictive analytics.

    View Solutions
  • Industrial Pre-Treatment

    Industrial pre-treatment is a crucial stage in the water cycle, occurring before wastewater enters municipal treatment facilities. It involves the removal of contaminants, pollutants, and other harmful substances from industrial wastewater streams to meet regulatory standards and protect the environment. This process typically includes physical, chemical, and biological treatment methods tailored to specific industrial processes and pollutants. By effectively pre-treating industrial wastewater, we can safeguard water quality, prevent damage to treatment infrastructure, and ensure the overall health of ecosystems downstream.

    View Solutions

Product Documentation

Filter Documents
Filtered by:
Remove all filters
Document Type
{{isTruncated ? openText : closeText}}

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

We’re sorry, your request didn’t return any documents.

{{data.didYouMean[0]}}? Please check your search term.

Please try again or contact us

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page
We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837