{{title}}
Request a quote {{contactOpenText}}
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

C12-17 Combustible Gas Detector

C12-17 Combustible Gas Transmitters are three-wire transmitters, operating from 24 VDC power supplies and transmitting a 4-20 mA signal proportional to 0-100% LEL (Lower Explosive Limit) of a particular gas or vapor. It's available either as a blind transmitter or with an integral LCD display that provides local indication of gas concentration, visible through the glass window in the explosion-proof housing.

Showing units in {{labelText}}
  • Parameters
    Other Gases
    Other Gases
Request a quote

Reliable Detection of Hazardous Concentrations of Combustible Gases

The C12-17 Combustible Gas Detector is a stand-alone gas transmitter designed to detect potentially hazardous concentrations of combustible gases in ambient air. Gases and hydrocarbon vapors, such as methane, propane, butane, gasoline, toluene, hydrogen and many others, can be reliably monitored in process buildings, analyzer enclosures, pump stations, gas compressor stations or anywhere gases or vapors may build up to explosive levels.

C12-17 Combustible Gas Detectors are three-wire transmitters available as either a blind transmitter or with an integral LCD display that provides local indication of gas concentration, visible through the glass window in the explosion-proof housing. Gas transmitter units supplied with the integral display also contain a single alarm set-point and relay for local alarm purposes. This integral relay is a latching alarm that can be reset with a magnetic tool without opening the enclosure.

C12-17 gas transmitters can be connected directly to PLC, DCS, or computer-based alarm systems without additional hardware. Combustible gas sensors are made up of two matched sensing elements, one active and one passive. Both are electrically heated and form two legs of a Wheatstone bridge circuit. When combustible gas contacts the sensor, the active element catalyzes the oxidation of gas heating the active element and changing its resistance. The passive element remains unchanged, resulting in a change in the bridge circuit proportional to the gas concentration. The C12-17 Combustible Gas Transmitter has explosion-proof sensor assemblies made of 316 stainless steel for maximum corrosion protection. A sinter-bonded flame arrestor provides the gas diffusion path to the sensing elements while maintaining the flame-proof integrity of the assembly. Sensing elements are specially designed for maximum poison resistance and long life in harsh industrial environments, with sensor life typically 2 years or more.

Features

  • Designed to detect potentially hazardous concentrations of combustible gases in ambient air
  • Connection to PLC, DCS or computer-based alarm systems without additional hardware
  • Explosion proof sensor assemblies

Market Applications

  • Environmental Monitoring

    ​Environmental monitoring solutions are designed to protect the world’s most precious resource. Instruments are deployable throughout the network to measure a variety of parameters, collect baseline data and deliver a deeper understanding of trends that enable early event detection and response.

    View Solutions
  • Wastewater Treatment

    Wastewater treatment facilities feature complex operational processes involving a wide range of flow measurement, water quality monitoring and toxic gas detection solutions, designed to conserve water, increase regulatory compliance and safeguard water quality, people and the environment. From individual monitors to multiparameter measurement, our versatile solutions deliver continuous and proactive monitoring for early event detection, odor control, pollution prevention, chemical management and toxic gas detection.

    View Solutions
  • Drinking Water Treatment

    Drinking water treatment facilities have the critical job of producing a safe supply of high-quality drinking water. Complex operational processes demand the highest flow meter accuracy and reliability, as well as long-term stability and a low cost of ownership. Badger Meter water treatment solutions meet the challenge, assisting utility customers with increasing compliance levels, protecting treatment assets and providing opportunities for process optimization using predictive analytics.

    View Solutions
  • Industrial Pre-Treatment

    Industrial pre-treatment is a crucial stage in the water cycle, occurring before wastewater enters municipal treatment facilities. It involves the removal of contaminants, pollutants, and other harmful substances from industrial wastewater streams to meet regulatory standards and protect the environment. This process typically includes physical, chemical, and biological treatment methods tailored to specific industrial processes and pollutants. By effectively pre-treating industrial wastewater, we can safeguard water quality, prevent damage to treatment infrastructure, and ensure the overall health of ecosystems downstream.

    View Solutions

Product Documentation

Filter Documents
Filtered by:
Remove all filters
Document Type
{{isTruncated ? openText : closeText}}

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

Product Data Sheets | English ATi Model C12-17
Manuals & Guides | English Model C12-17 LEL Transmitter
Manuals & Guides | English C12-17 Combustible Gas Transmitter
Specifications | English Combustible Gas Sensor/Transmitter

We’re sorry, your request didn’t return any documents.

{{data.didYouMean[0]}}? Please check your search term.

Please try again or contact us

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page
We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837