{{title}}
Request a quote {{contactOpenText}}
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

HR-E® LCD Encoders

High Resolution LCD Encoders are straight reading, permanently sealed, electronic LCD absolute encoders with a field-programmable option. They use industry standard ASCII communication protocols to provide high resolution encoded output.

Showing units in {{labelText}}
  • Temperature Range
    -40...60° C
    -40...140° F
Request a quote

Dependable Service. Peace of Mind.

HR-E LCDs are factory programmed to customer specifications and feature an LCD display that toggles between 6- and 9-digit visual resolution, rate of flow and meter model with alarms and indicators to keep you informed. 

  • Reliable Design. Constructed with a 20-year battery life and built with unique adhesive sealing to withstand harsh environments, including flooded pits. 
  • Increased Security. Built with tamper-resistant features such as register removal and magnetic tamper indicators to provide utilities with peace of mind. 
  • Enhanced Data. Provides consistent, high-resolution data to utilities to help detect leaks and reverse flows to avoid potential revenue loss.


Specifications

Showing units in {{labelText}}
  • Temperature Range
    -40…60 °C
    -40 to 140 °F
  • Units of Measure
    U.S. Gallons, Cubic Feet, Cubic Meters, clearly identified on encoder face
    U.S. Gallons, Cubic Feet, Cubic Meters, clearly identified on encoder face
  • Electronic Resolution
    9-digit resolution for AMR/AMI solutions
    9-digit resolution for AMR/AMI solutions
  • Signal Type
    3-wire synchronous for AMR/AMI solutions
    3-wire synchronous for AMR/AMI solutions
  • Encoder Display
    Straight reading, permanently sealed, electronic LCD absolute encoder with field-programmable option
    Straight reading, permanently sealed, electronic LCD absolute encoder with field-programmable option
  • Status Indicators
    Electronic and visual icons for: meter functioning correctly, meter alarm (indicates temperature limits exceeded, magnetic tamper or encoder removal), reverse flow, suspected leak, 30-day no usage, end of battery life
    Electronic and visual icons for: meter functioning correctly, meter alarm (indicates temperature limits exceeded, magnetic tamper or encoder removal), reverse flow, suspected leak, 30-day no usage, end of battery life

Market Applications

  • Building Design, HVAC & Plumbing

    Flow instrumentation solutions are a crucial aspect of building design, construction and operation for apartments, hospitals, schools, factories and other facilities. From HVAC and grounds management to plumbing and water services, our flow meters are specifically designed to provide solutions that are accurate and reliable, even under the most challenging conditions.

    View Solutions
  • Customer Water Usage

    Utilities play a pivotal role in drinking water management by ensuring the safe and reliable delivery of clean water to communities. Operating and maintaining vast infrastructure networks, utilities are responsible for sourcing, treating, and distributing water while adhering to stringent quality standards. These applications demand the highest level of accuracy, flexibility and reliability. Our water meters and flow monitoring technologies, coupled with powerful analytics software, provide end-to-end solutions that generate revenue, conserve water and improve customer service.

    View Solutions

Software

Filter Downloads
Filtered by:
Remove all filters
Product Line
{{isTruncated ? openText : closeText}}
Product / Model

Before filtering by product or model, please select a brand from the filter above.

{{isTruncated ? openText : closeText}}
Download Type
Language
{{isTruncated ? openText : closeText}}

Displaying {{pageRange}} of {{data.totalResults}}

Software | Version v1210-20100408 | Updated January 22, 2024 | 2.32 MB IR Programming Cable Driver AquaCUE ; BEACON ; Dynasonics ; E-Series ; High Resolution Encoders ; ORION See Release Notes
Software | Version v1210-20100408 | Updated January 22, 2024 | 2.32 MB IR Programming Cable Driver AquaCUE ; BEACON ; Dynasonics ; E-Series ; High Resolution Encoders ; ORION See Release Notes

We’re sorry, your request didn’t return any software or firmware.

Please try again or contact us

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page

Product Documentation

Filter Documents
Filtered by:
Remove all filters
Document Type
{{isTruncated ? openText : closeText}}

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

We’re sorry, your request didn’t return any documents.

{{data.didYouMean[0]}}? Please check your search term.

Please try again or contact us

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page
We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837