{{title}}
Request a quote {{contactOpenText}}
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

Insertion Style Flow Sensors - 220 Series

220 Series sensors are specifically designed for installation in underground vaults that might be subjected to flooding. As the liquid flow turns the impeller, a low impedance 8V DC square wave signal is transmitted with a frequency proportional to the flow rate. This signal can travel up to 2,000 feet between the sensor and the display unit without the need for amplification.

Showing units in {{labelText}}
  • Size
    12...101 mm
    1/2...4 in.
  • Temperature Range
    Up to 105 °C
    Up to 221 °F
  • Flow Range
    0.9...9.14 m/sec
     0.3...30 ft/sec
  • Pressure Range
    Up to 27 bar
    Up to 400 PSI
  • Accuracy
    ±1.0%
    ±1.0%
Request a quote

Provides higher, more consistent torque than four-bladed impeller designs.

Used in most general flow measuring applications in metallic or non-metallic pipes.

  • Cost savings over other systems offered on the market today
  • Impeller, bearing and shaft are easily replaced in field without changing calibration
  • Impeller shape coupled with the absence of magnetic drag provides accuracy and repeatability


Specifications

View & Configure CAD/BIM Drawings Download CSI Specifications
Showing units in {{labelText}}
  • Temperature Ratings
    Standard Version: 105 °C continuous service
    High Temperature Version: 141 °C continuous service; 150 °C peak temperature (limited duration)
    Standard Version: 221 °Fcontinuous service
    High Temperature Version: 285 °F continuous service; 305 °F peak temperature (limited duration)
  • Pressure Ratings
    At 100° F: 400 PSI
    At 300° F (High Temperature Version Only): 325 psi
    At 100° F: 400 PSI
    At 300° F (High Temperature Version Only): 325 psi
  • Recommended Design Flow Range
    0.5…30 ft/sec Initial detection below 0.3 ft/sec
    0.5…30 ft/sec Initial detection below 0.3 ft/sec
  • Accuracy
    ± 1.0% of full scale over recommended design flow range
    ± 1.0% of full scale over recommended design flow range
  • Repeatability
    ± 0.3% of full scale over recommended design flow range
    ± 0.3% of full scale over recommended design flow range
  • Linearity
    ± 0.2% of full scale over recommended design flow range
    ± 0.2% of full scale over recommended design flow range
  • Transducer Excitation
    Supply voltage = 8V DC min. 35V DC max.
    Quiescent current = 600 µA (typical)
    OFF State (VHigh) = Supply voltage – (600 µA * Supply impedance)
    ON State (VLow) = 1.2V DC @ 40 mA (15 Ω + 0.7V DC)
    Supply voltage = 8V DC min. 35V DC max.
    Quiescent current = 600 µA (typical)
    OFF State (VHigh) = Supply voltage – (600 µA * Supply impedance)
    ON State (VLow) = 1.2V DC @ 40 mA (15 Ω + 0.7V DC)
  • Output Frequency
    3.2…200 Hz
    3.2…200 Hz
  • Output Pulse Width
    5 msec ±25%
    5 msec ±25%
  • Electrical Cable for Standard Sensor Electronics
    20 ft (6 m) of 2-conductor 20 AWG shielded UL type PTLC wire provided for connection to display or analog transmitter unit. Rated to 221° F (105° C). May be extended to a maximum of 2000 ft (610 m) with similar cable and insulation appropriate for application.
    20 ft (6 m) of 2-conductor 20 AWG shielded UL type PTLC wire provided for connection to display or analog transmitter unit. Rated to 221° F (105° C). May be extended to a maximum of 2000 ft (610 m) with similar cable and insulation appropriate for application.
  • Electrical Cable for IR Sensor Electronics
    48 in. (122 cm) of UL style 116666 copper solid AWG 18 wire with direct burial insulation. Rated to 221° F (105° C).
    48 in. (122 cm) of UL style 116666 copper solid AWG 18 wire with direct burial insulation. Rated to 221° F (105° C).
View all Specifications

Market Applications

  • Building Design, HVAC & Plumbing

    Flow instrumentation solutions are a crucial aspect of building design, construction and operation for apartments, hospitals, schools, factories and other facilities. From HVAC and grounds management to plumbing and water services, our flow meters are specifically designed to provide solutions that are accurate and reliable, even under the most challenging conditions.

    View Solutions
  • Wastewater Treatment

    Wastewater treatment facilities feature complex operational processes involving a wide range of flow measurement, water quality monitoring and toxic gas detection solutions, designed to conserve water, increase regulatory compliance and safeguard water quality, people and the environment. From individual monitors to multiparameter measurement, our versatile solutions deliver continuous and proactive monitoring for early event detection, odor control, pollution prevention, chemical management and toxic gas detection.

    View Solutions
  • Industrial Process

    The measurement and monitoring of flow, water quality and toxic and combustible gas plays a vital role in industrial processes for consistent delivery of quality control, personnel safety, environmental protection, process monitoring and optimization. Our comprehensive range of robust, real-time and reliable instrumentation provides dependable solutions that are easy to install, simple to maintain, creates safe areas of work and deliver increased regulation compliance.

    View Solutions

Product Documentation

Filter Documents
Filtered by:
Remove all filters
Document Type
{{isTruncated ? openText : closeText}}

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

We’re sorry, your request didn’t return any documents.

{{data.didYouMean[0]}}? Please check your search term.

Please try again or contact us

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page
We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837